Quick Answer
A door closer for double doors is specified leaf by leaf, then checked as one opening. Confirm the active and inactive leaf widths and weights, which leaf must close first, the overlap or center gap, and whether a coordinator is needed. Then choose the mounting method and functions for each leaf. OUBAO’s 9016BC covers 15–150 kg leaves up to 1,400 mm wide in one non-handed model, while the 700 Series offers five sizes for lighter leaves.
Why Does a Door Closer for Double Doors Start With the Pair Layout?
Because two closers can each be correctly sized and still work poorly as a pair. A double door is one opening with two leaves that share a meeting point, a closing order and often an overlap. Each closer affects the other leaf’s clearance, latch position and closing speed. The pair therefore needs to be reviewed as a system, not as a quantity of two.
Start with the opening drawing. Mark the hinge side of each leaf, the direction of swing, the frame stops and the meeting edges. Identify which leaf people use every day and which leaf stays closed most of the time. These two roles determine how the closers, arms and any sequencing hardware will interact.
This is also the point where a buyer should stop comparing catalog photos. A photo shows the closer body; it does not show whether the arm will clear an astragal, whether the inactive leaf has room to close first, or whether the frame can accept the chosen bracket. A simple elevation with both leaves drawn in the closed position catches these issues earlier than a site visit after delivery.
Size the Active and Inactive Leaves Separately
Size each leaf separately using its own width and weight. Do not add the two leaf widths together and size one closer for the whole opening, and do not assume both leaves are equal. The active leaf is the leaf normally opened first; the inactive leaf is the second leaf, often secured until the active leaf is opened. Either leaf can be wider, heavier or fitted with different hardware.
Door weight means the complete leaf assembly, including the door blank, glass, reinforcement, locks and any attached hardware. A scale reading or the door maker’s calculated weight is more reliable than an estimate based on thickness alone. Width is measured from the hinge edge to the lock edge, not across the full opening.
Use the closer maker’s width and weight chart as a starting point, then check the mounting position. The same leaf may fall into a different power range when mounted on the frame face, the header or a parallel arm bracket. OUBAO’s door closer size chart explains how width, weight and power size relate.
Unequal leaves are common. A wide active leaf may need a larger closer than a narrow inactive leaf. If one leaf is used constantly and the other only occasionally, the duty pattern can also differ. Record both leaves on the RFQ rather than describing the opening as one average size.

Overlap Changes the Hardware Set
Overlap changes the clearance at the center of the opening. It is the distance one leaf sits in front of the other when the doors are closed. Many pairs use an overlapping astragal—a strip fitted to one leaf to cover the gap at the meeting edge—or a stepped meeting stile so the leaves seal against air, water and sound. That overlap can also interfere with a closer arm, a pull or a latch.
Measure the overlap and the center gap with the doors closed. Take a photo looking straight at the meeting edges, with a tape measure visible. Then check the same area with one leaf open and the other closed. The supplier needs to see where the arm travels, not only where it sits at rest.
A pair with no overlap still needs a clearance check. Projecting hardware on one leaf can reduce the space available to the other. The frame stop, the door thickness and the position of any weather seal all affect how much room the closer arm has. If the opening uses a coordinator or another sequencing part, include it in the same drawing so the parts are checked together. A door closer for double doors should therefore be checked at the meeting edges, not only at the hinge.
How Do You Choose the Closing Sequence?
Choose the sequence from the door design, then select hardware that enforces it. In a typical pair, the inactive leaf closes first and the active leaf closes second, so the active leaf can latch over the inactive leaf. A coordinator, also called a sequencer, holds the active leaf open while the inactive leaf closes. The active leaf is then released to finish its swing.
Not every pair needs a coordinator. A pair with no overlap, separate latch points and enough clearance may close correctly with two independently adjusted closers. A coordinator becomes important when the leaves overlap, when an astragal or seal sits between them, or when one latch would otherwise strike the other leaf.
Two identical closers do not guarantee the right order. Closing speed and latching speed are adjusted separately on each closer, and site conditions change both. A heavy active leaf may close faster than expected; a light inactive leaf may hesitate at the latch. The sequence should be checked with the actual leaves, not assumed from the model numbers.
Ask the supplier to show the intended sequence on the drawing: which leaf closes first, where the coordinator or stop is fitted, and how the active leaf clears the inactive leaf. This turns a verbal instruction into something the installer can follow.
Mounting and Function Options for the Quote
Put the mounting method and every function on the quote, because both change the price and the installation. Standard mounting fixes the closer to the face of the door. Parallel-arm mounting places the closer on the frame head with the arm running parallel to the door. Top-jamb mounting fixes the closer to the header and uses a different arm geometry. Slide-arm mounting uses a track and is useful where the door face needs to stay clear.
The right choice depends on frame depth, header space, door thickness and whether the door opens against a wall. A narrow frame reveal may not accept a standard bracket. A deep header may suit top-jamb mounting but leave too little room for a parallel arm. The mounting method should be confirmed before the door is prepared for fixings.
Functions matter as much as mounting. Adjustable closing speed controls the main swing; latching speed controls the final few degrees. Back check resists a door that is pushed open too fast. Delayed action holds the door open briefly before it starts to close. A hold-open arm keeps the door open at a set angle, which is useful for carts, deliveries or ventilation but unsuitable where the door must always close.
The hold-open and non-hold-open comparison explains where each option fits. Specify the function for each leaf separately. The active leaf may need a hold-open arm while the inactive leaf does not, and mixing functions is normal on a double door.
How Do the 9016BC and 700 Series Compare?
The door closer range includes both series, along with other models for different leaf sizes. Start with the leaf that sets the heaviest requirement, then confirm that the other leaf also has a suitable model and arm.
The 9016BC is a flexible choice for a wide range of leaves. One non-handed model covers leaves from 15 kg to 150 kg and up to 1,400 mm wide, with adjustable closing force from EN 1 to 6. It offers standard, parallel, top-jamb and slide-arm mounting, plus adjustable closing and latching speed, back check, optional delayed action and an optional hold-open arm. The 9016BC is UL and UL 10C listed and meets ANSI 156.4 Grade 1.
The 9016 adjustable-power closer suits buyers who want one model to cover mixed leaf sizes, especially when the active and inactive leaves differ. Its adjustable power can reduce the number of variants a distributor carries, although each leaf still needs its own setting and mounting check.
- Residential & Apartments : Entrance doors, common areas and multi-family housing This series is designed for various door types, including wooden and metal doors.

The 700 Series classic closer uses five models with fixed power ranges. The 701 covers 15–30 kg and up to 750 mm, the 702 covers 25–45 kg and up to 850 mm, the 703 covers 40–65 kg and up to 950 mm, the 704 covers 65–85 kg and up to 1,100 mm, and the 705 covers 80–120 kg and up to 1,250 mm. Power sizes run from 1 to 5 by model. All are non-handed and offer standard, parallel and top-jamb mounting; the 704 and 705 also offer slide-arm mounting. Closing and latching speed are adjustable, with optional built-in hold-open on the 701–703 and optional back check on the 704–705.
Choose the 700 Series when a fixed model per leaf keeps ordering and stocking simple. Choose the 9016BC when leaf sizes vary or when one adjustable model is more useful than five fixed ranges. OUBAO manufactures both series and can discuss model configuration, branding and packaging for OEM or ODM programs.
- This series is designed for various door types, including wooden and metal doors. Yes, this series features a non-handed design.

Complete Double-Door Closer RFQ
A complete RFQ for a door closer for double doors lets the supplier quote the whole opening without guessing. A double door closer package should list the door type and material, the width and weight of each leaf, the hinge handing, the frame type and the mounting method. Add the overlap or center gap, the intended closing sequence and whether a coordinator is required.
List the functions for each leaf: hold-open or non-hold-open, back check, delayed action, and any special arm or bracket. State the finish and color, the fasteners needed for the door material, and whether left and right leaves must match visually. If the pair is part of a larger project, include the door schedule and the required quantity.
Ask for the installation instructions and the model-specific documents needed for the target market. Product drawings, templates and available documentation can be requested through the download center. Confirm that the documents match the exact model, mounting and function on the quote, not only the series name.
Finally, separate the closer body, arm, bracket, coordinator and fasteners on the quotation. A low unit price can hide a missing bracket or an arm that does not suit the frame. A line-by-line quote makes the complete package comparable.
Final Thoughts / Next Step
Specify a double door closer by sizing each leaf, checking the pair at the meeting edges, and confirming the closing sequence before choosing models. The 9016BC and 700 Series cover different buying preferences, but neither replaces a clear opening schedule. Send OUBAO the door type, leaf width and weight, mounting method, target market, required documents and estimated quantity through the contact page. The team can confirm the pair configuration and prepare a quotation.