Quick Answer
An electric strike is the frame-mounted receiver that holds a door’s mechanical latch and releases it electronically. It adds card, keypad, or remote access without replacing the existing lockset. The buying decision is mostly about compatibility: latch type, faceplate size, frame cutout, voltage, and fail-safe or fail-secure release. OUBAO’s seven OB-SK models give buyers standard, long-faceplate, narrow-frame, L-shaped, and compact starting points, with 12 VDC standard and 24 VDC on request. The opening, not the catalogue, should drive the shortlist.
What Is an Electric Strike?
An electric strike is a locking component installed in the door frame, in the position where a fixed strike plate would normally sit. Its opening receives the door’s latch bolt—the spring-loaded metal tongue that extends from the lock—and its keeper holds that latch closed. When an access controller releases the strike, the keeper moves aside and the latch can clear the frame.
The important point for buyers is that an electric strike does not replace the door’s mechanical lock. It works with the existing latch, so the door can keep its handle, cylinder, and keys while electronic credentials control entry. That makes it a practical choice for retrofit projects and for buildings that want to add access control without changing every lockset.
An electric strike is also only one part of the system. It needs a controller, a reader or keypad, a power supply, and a release device such as an exit button. If you are comparing complete lock types rather than strike models, OUBAO’s electric strike range is a useful starting point for frame, faceplate, and voltage options.
How Does an Electric Strike Work?
Buyers often ask, “How does an electric strike work?” The sequence is simple:
- The door closes and the latch drops into the strike opening.
- The keeper holds the latch, so the door stays closed.
- A card reader, keypad, or remote release sends a signal to the access controller.
- The controller releases the strike, the keeper clears the latch, and the door can be pushed or pulled open.
- When the door closes again, the latch re-enters the strike and is held.
The strike does not pull the door open. It only releases the latch. Someone still has to open the door, or a door operator must do it.
The release method depends on the strike’s power logic. A fail-safe strike uses power to stay locked and releases when power is removed. A fail-secure strike stays locked without power and uses power to release. That difference affects the power supply, the controller wiring, and what happens during an outage, so it should be decided before the model.
Should You Choose Fail-Safe or Fail-Secure?
Choose fail-safe when the door must release if power fails. Choose fail-secure when the door must stay locked during a power failure and the building has a separate, approved way for people to exit. Neither mode is automatically correct for every opening; the door’s role, the exit route, and local requirements decide.
| Mode | What happens when power fails | Why buyers choose it | What to confirm |
|---|---|---|---|
| Fail-safe | The strike releases; the door can open | Emergency release of the controlled door; fire-alarm integration | The power supply keeps the strike locked in normal operation, and the controller releases it on alarm |
| Fail-secure | The strike stays locked | Higher security at the controlled entrance; release only after a valid credential | The exit-side hardware and release arrangement, plus backup power if the project requires it |
Across the OB-SK range, fail-safe models draw 250 mA in normal locked operation. Fail-secure models draw 650 mA when releasing; the OB-SK23C is fail-secure only and draws 900 mA. Those figures matter when one power supply serves several doors.
If you are still deciding between a strike and a magnetic lock, this comparison of magnetic locks and electric strikes explains where each fits.
- Working voltage — OB-SK20: 12VDC(24VDC upon request) Working current — OB-SK20: Fail safe is 250mA, Fail secure is 650mA

Latch and Faceplate Fit Checks
Only if the latch, faceplate, and frame cutout match the electric strike. The strike opening must accept the latch’s type and projection, the faceplate must cover the frame preparation, and the keeper must hold the latch without binding. A strike that looks similar but has the wrong opening or screw spacing will not install cleanly.
Check these four items before comparing prices:
- Latch type and projection: measure how far the latch extends from the door edge and photograph the latch face.
- Existing strike plate: record its length, width, screw-hole spacing, and cutout size.
- Frame pocket: measure the depth and height available behind the faceplate.
- Door gap: check the gap between the door edge and frame; the latch must enter the strike without rubbing.
Longer faceplates suit frames with a longer preparation or an existing plate that needs more coverage. OUBAO’s OB-SK22 uses a 200 mm faceplate, while the compact OB-SK25 is 124 mm long. The difference is not cosmetic; it changes which frames the strike can cover.

Door and Frame Conditions That Matter Most
The frame material and profile decide whether an electric strike can be mounted and which faceplate shape fits. Hollow metal frames are common for commercial access control because they provide a stable pocket for the strike. Wood frames can work where there is enough material for the cutout. Glass doors need a suitable narrow-stile frame and mounting arrangement; the strike is not fixed directly to the glass.
Narrow-profile and specialty doors are where model choice becomes more specific. The OB-SK23 and OB-SK23C use a 250 mm long frame that fits narrow door sections. The OB-SK24 has an L-shaped body for flexible installation on narrow-profile doors. For a standard commercial frame, the OB-SK20 is the simpler starting point.
On fire-rated doors, the strike must suit the rated door assembly and the hardware schedule for the project. Do not choose a strike for a fire door only by faceplate size; the assembly, latch, and approval need to be considered together.
If the frame cannot accept a strike cutout, an electric bolt lock may be an alternative. It installs differently and locks with a bolt rather than a keeper, so compare the frame and door preparation before switching.
Electrical Details for the Spec
Put voltage, current, release mode, and signal requirement on the spec before comparing quotes. The standard voltage for the OB-SK range is 12 VDC; 24 VDC is available on request. Most models offer fail-safe, fail-secure, fail-safe with signal, and fail-secure with signal. The OB-SK23C is fail-secure only.
The controller must provide the release signal the strike expects, and the power supply must deliver the current at the door. Voltage drop over a long cable run can leave a strike with less power than it needs, so include the cable distance and supply location in the project information. If the controller also manages readers, exit buttons, and alarm release, confirm its output type and timing with the access controller selection.
The rated operating temperature is −20°C to 50°C. That range suits many indoor and protected entrance environments. For an exposed exterior door, include the enclosure and project conditions in the enquiry so the mounting arrangement can be checked.
Which OUBAO Electric Strike Matches Your Opening?
Start with the faceplate and frame, then choose the release mode. OUBAO’s OB-SK range gives buyers seven models to compare, from a standard stainless-steel strike to long-frame and compact versions. All seven are CE certified, and all except the OB-SK23C offer fail-safe, fail-secure, and signal variants.
| Model | Typical starting point | Size (mm) | Static strength | Notes |
|---|---|---|---|---|
| OB-SK20 | Standard commercial frame and latch | 150 × 28 × 34 | 350 kg | Stainless steel; standard faceplate |
| OB-SK21 | Standard latch with a wider faceplate | 150 × 40 × 34 | 350 kg | Stainless faceplate; black housing |
| OB-SK22 | Frame that needs a longer faceplate | 200 × 40 × 34 | 350 kg | Long stainless faceplate |
| OB-SK23 | Narrow-profile or specialty frame | 250 × 25 × 34 | 350 kg | Long frame |
| OB-SK23C | Narrow-profile frame with a fail-secure requirement | 250 × 25 × 31.6 | 300 kg | Fail-secure only; 900 mA |
| OB-SK24 | Narrow-profile frame with limited space | 150 × 37 × 34 | 350 kg | L-shaped; metal construction |
| OB-SK25 | Compact opening | 124 × 43 × 32 | 1,000 kg | Stainless faceplate; black housing |
The OB-SK20 is the standard starting model when the frame preparation is conventional and the latch is a standard type. Use the static-strength figures to compare models, then confirm the installation details for the opening.
Quote Request Checklist
Send the door and frame details, latch photos, electrical requirements, destination market, and quantity. That is enough for OUBAO to narrow the seven models to a specific faceplate, release mode, and voltage, then confirm the documents available for the project.
A useful electric strike enquiry includes:
- Door type and material, single or double leaf, door width and weight, and how the door is installed.
- Photos of the frame edge, existing strike plate, and latch, with a ruler or tape measure in frame.
- Faceplate length and width, screw-hole spacing, cutout dimensions, and available frame depth.
- Required voltage, fail-safe or fail-secure operation, signal requirement, and controller model.
- Finish, branding, packaging, and any private-label requirements for the OEM/ODM program.
- Destination market, required certificate or datasheet, estimated quantity, and target shipment date.
If the project includes readers, keypads, exit buttons, and power supplies, send the full door list rather than the strike alone. The controller and lock have to work as one release circuit, and checking them together avoids a late change after the order.
Final Thoughts / Next Step
An electric strike is a straightforward way to add electronic access to a door that already has a mechanical latch, but it is a compatibility purchase rather than a universal part. Match the latch and faceplate first, then confirm the frame, voltage, current, and release logic. OUBAO’s seven OB-SK models cover standard, long-faceplate, narrow-frame, L-shaped, and compact openings, with CE certification and 12 VDC standard or 24 VDC on request.
- Magnetic locks use electromagnetic force to secure a door and release it when power is removed. Electric strikes work with a mechanical latch and can be fail-safe or fail-secure.

Send your door type, door weight and width, installation photos, target market, required documents, and quantity to OUBAO for a model-specific recommendation and quote.